A medium length electromechanicals barrier suitable for yard, forecourts, private properties and industrial or commercial access roads.
The beam can be up to 5 meters in length with or without hanging rack. Equipped with the various accessories available, the normal is a completely safe and functional barrier. The boom can be elevated manually by operating a handle in the event of a power failure. An electromechanical barrier intended for special purposes. The beam can be up to 5 metres in length (6 metres with hanging rack). Control boxes are either galvanized with a stoved paint finish or in maximum durability under exposure to different operating environments, equipped with the various accessories available, the Industrial is a completely safe and functional barrier. The boom can be elevated manually by operating a handle in the event of power failure.
Signal barriers allowing rapid and tight control internally of parking facilities, residential complexes, etc. Booms are available in lengths from 1 to 5 metres, and all drive units are ventilated. Control boxes are either galvanized with a stoved paint finish, so as to ensure maximum durability under exposure to different operating environments. Equipped with the various accessories available, Signal barriers are completely safe functional. The boom can be released with a key and operated manually in the event of a power cut.
Choice of Colors: Beige, Blue & Striking Orange
Features:
- Adjustable Speed
- Built in Control Board
- 24v D.C. Motor
- Slow Down Device When Closing / Opening
- Continuous Hazard-free Use
- Detection Of The Reopening With Amperometric Device
- CS 650 Model Is Designed To Control Roads Up To 5 Meters
- May Be Equipped With Emergency Batteries
Image Gallery
Video
Implementation at Four Seasons Hotel :Specification
| Data | CS 650 | ||
| Motor Power Supply |
|
||
| Motor Power | 190 W 24Vdc | ||
| Motor Current Drain | 12 Amps | ||
| Shaft Torque | 210 NM | ||
| Gearing Down Ratio | 0.005 | ||
| Operating Temperature (C) | -20/+70 | ||
| Opening Time | 2-6 SEC | ||
| Lubrication | GREASE | ||
| Safety Device | Mechanical clutch | ||
| Dimensions | 320 x 300 x H1030 | ||
| Operating Limits | 2 – 4.5 METERS |